Product Features

  • VRLA (Valve Regulated Lead Acid) battery
  • Absorbent Glass Mat (AGM) technology, maintenance-free, up to 99% gas recombination efficiency
  • Pure lead construction with proprietary formulation elements
  • Designed for high-rate UPS and float standby power applications
  • Manufactured to IEC 60896-21/22:2004 and UL1989 certified (MH14533)

Application Scenarios

  • Front terminal for long-duration backup in data centers
  • UPS backup battery supporting high-rate discharge
  • Front-access wiring for backup power in large equipment rooms
  • Long-duration backup power for communication equipment rooms
  • High-rate performance for industrial control backup
  • Network equipment paired with uninterruptible power supply

Product parameters

  • Model:XPL9000FT
  • Voltage:12 Vdc
  • Nominal Capacity:9000W @5min-rate
  • Watts per Cell:2069.83 (30-Sec 1.67 VPC @ 25°C)
  • Watts per Cell:1403.33 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:907.67 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:75.00 A
  • Max. Discharge Current:1900 A
  • Short Circuit Current:5102 A
  • Internal Resistance:1.86 mΩ
  • Terminal Type:I2 thread lead alloy terminal to accept M6 bolt
  • Terminal Torque:51.7±10.3 Kgf·cm / 44.9±9.0 Lbf·in / 5.1±1.0 N·m
  • Container Material:PP (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:69.50 / 153.22 kg / lb.
  • Length (L):558.0±2.5 / 21.97±0.10 mm / in
  • Width (W):126.0±1.5 / 4.96±0.06 mm / in
  • Height (H):323.0±2.5 / 12.72±0.10 mm / in
  • Design Life:Up to 10 years in standby service at 25°C; Eurobat (20°C): >12 years, Very Long Life
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB XPL9000FT, part of the XPL-FT series, is a 12V front terminal pure lead valve-regulated sealed lead-acid battery that uses Absorbent Glass Mat (AGM) technology, achieves 99% gas recombination efficiency, and is maintenance-free. Manufactured to IEC 60896-21/22:2004 and recognized to UL1989 (MH14533), it is designed primarily for high-rate UPS and data center backup power applications. Regarding electrical specifications, the XPL9000FT has a nominal voltage of 12 Vdc and a nominal capacity of 9000W @5min-rate (9.60V per PCS @ 25°C). Per-cell power performance: 2069.83 W/cell at 30 seconds to 1.67 VPC; 1403.33 W/cell at 5 minutes to 1.67 VPC; and 907.67 W/cell at 15 minutes to 1.67 VPC. Maximum charge current is 75.00 A, maximum discharge current is 1900 A, short-circuit current is 5102 A, and internal resistance is 1.86 mΩ. For charging conditions and temperature range, at 25°C the float charge voltage is 13.5 - 13.8 Vdc/battery and the equalize charge voltage is 14.4 - 15.0 Vdc/battery. Operating temperature: nominal 25°C; discharge from -15°C to 50°C; charge and storage from -15°C to 40°C. For self-discharge, less than 10% after 90 days at 25°C, with storage up to 6 months, extendable to 10 months with equalize charging; a full charge is required before use, and if storage temperature exceeds 25°C, recharge earlier. In terms of construction, the XPL9000FT case material is PP (UL 94-HB), with a flame-retardant (94-V0) version available on request. Terminals are I2 threaded lead alloy, accept M6 bolts, and the recommended torque is 51.7±10.3 Kgf∙cm / 44.9±9.0 Lbf∙in / 5.1±1.0 N∙m. Weight is 69.50 kg (153.22 lb), and dimensions are length 558.0±2.5 mm, width 126.0±1.5 mm, height 323.0±2.5 mm. Design life reaches 10 years under standby float charging at 25°C and meets the Eurobat long life standard (greater than 12 years at 20°C). With its front terminal design and pure lead construction, the XPL9000FT suits high-rate backup applications such as data center uninterruptible power supplies, providing reliable backup power for critical equipment.