CSB XHRL12600WFTFR 12V Valve-Regulated Sealed Lead-Acid Battery with Front Terminal Design
The CSB XHRL12600WFTFR is a 12V front terminal valve-regulated sealed lead-acid battery belonging to the XHRL-FT series. Utilizing AGM technology, it delivers a nominal capacity of 600W @ 15min-rate, primarily designed for data center UPS and other high-rate float standby applications.
Taobao store
WeChat procurement
Product Features
- VRLA (Valve Regulated Lead Acid) battery
- AGM (Absorbent Glass Mat) technology, maintenance-free, with gas recombination efficiency up to 99%
- Pure lead construction with proprietary formulation elements
- Designed for high-rate UPS and float standby power applications
- Manufactured to IEC 60896-21/22:2004 and UL1989 certified (MH14533)
Application Scenarios
- Front-terminal backup power for data center UPS
- High-rate discharge for telecom room standby applications
- Fast-discharge battery for rack-mounted UPS
- Emergency power source for edge data centers
- Backup power upgrade with front-access cabinet wiring
- UPS backup power for industrial control cabinets
Product parameters
- Model:XHRL12600WFTFR
- Voltage:12 Vdc
- Nominal Capacity:600W @ 15min-rate
- Watts per Cell:1766.00 (30-Sec 1.67 VPC @ 25°C)
- Watts per Cell:1144.17 (5-Min 1.67 VPC @ 25°)
- Watts per Cell:642.50 (15-Min 1.67 VPC @ 25°)
- Max. Charge Current:60.00 A
- Max. Discharge Current:1550 (5sec)
- Short Circuit Current:4132 A
- Internal Resistance:2.01 mΩ
- Terminal Type:I2 thread lead alloy terminal to accept M6 bolt
- Terminal Torque:51.7±10.3 Kgf·cm / 44.9±9.0 Lbf·in / 5.1±1.0 N·m
- Container Material:PP (UL 94-HB) standard, flame-retardant (94-V0) available upon request
- Weight:49.70 / 109.57 kg / lb.
- Length (L):558.0±2.5 / 21.97±0.10 mm / in
- Width (W):126.0±1.5 / 4.96±0.06 mm / in
- Height (H):255.0±2.5 / 10.04±0.10 mm / in
- Design Life:Up to 10 years in standby service at 25°C; Eurobat (20°C): 12+ years, Very Long Life
- Float Charging Voltage:13.5 - 13.8 Vdc/battery
- Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
- Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
Product details
The CSB XHRL12600WFTFR is a 12V front terminal valve-regulated sealed lead-acid battery in the XHRL-FT series. Compared to the XHRL series, this series adopts a front terminal configuration, making front-of-cabinet wiring and maintenance more convenient, suitable for data center uninterruptible power supplies and other float standby applications requiring high-rate discharge. The battery uses Absorbent Glass Mat (AGM) technology with a gas recombination efficiency of up to 99%, is maintenance-free, and is constructed with pure lead and proprietary elements.
In terms of power, this model has a nominal capacity of 600W @ 15min-rate (conditions: 10.02V per PCS, 25°C). At 25°C, the power per cell is 1766.00 W/cell at 30 seconds to 1.67 VPC, 1144.17 W/cell at 5 minutes to 1.67 VPC, and 642.50 W/cell at 15 minutes to 1.67 VPC. Electrical parameters include: maximum charge current 60.00 A, maximum discharge current 1550 (5sec), short-circuit current 4132 A, internal resistance 2.01 mΩ.
Charging and temperature conditions are as follows: at 25°C, float charge voltage is 13.5 to 13.8 Vdc/battery, equalize charge voltage is 14.4 to 15.0 Vdc/battery. Nominal operating temperature is 25°C, discharge temperature range is -15°C to 50°C, charge and storage temperature range is -15°C to 40°C. Self-discharge at 25°C is less than 10% after 90 days; can be stored for 6 months, extendable to 10 months with equalizing charge, requires full charge before use; if storage temperature exceeds 25°C, recharge is required earlier.
Dimensions and construction: battery length 558.0±2.5 mm, width 126.0±1.5 mm, height 255.0±2.5 mm, weight 49.70 kg. Terminals are I2 thread lead alloy terminal, accepting M6 bolts, terminal torque is 51.7±10.3 Kgf∙cm, 44.9±9.0 Lbf∙in, or 5.1±1.0 N∙m. The case is made of PP (UL 94-HB) material; a flame-retardant 94-V0 version is available upon request.
Design life: up to 10 years in float standby service at 25°C; over 12 years long life under Eurobat (20°C) conditions. Manufactured in accordance with IEC 60896-21/22:2004 and UL1989 Recognized (MH14533). With front terminals and high-rate power output, this model is suitable for data center UPS and other float standby power systems, allowing installation and maintenance from the front of the cabinet.