  • Battery designed with valve-regulated lead-acid (VRLA) technology
  • Maintenance-free through absorbent glass mat (AGM) technology, with gas recombination efficiency up to 99%
  • Features a pure lead structure with proprietary additives
  • Built for high-rate UPS and float standby power applications
  • Manufactured to IEC 60896-21/22:2004 and UL1989 recognized (MH14533)

Application Scenarios

  • Rapid-discharge battery packs for rack-mount UPS
  • UPS backup solutions in industrial control cabinets
  • High-rate discharge standby power for communication equipment rooms
  • Emergency power for edge data centers
  • Backup power system retrofit for front-access wiring cabinets
  • Backup support for front-terminal UPS in data centers

Product parameters

  • Model:XHRL12900WFTFR
  • Voltage:12 Vdc
  • Nominal Capacity:900W @ 15min-rate
  • Watts per Cell:2069.83 (30-Sec 1.67 VPC @ 25°C)
  • Watts per Cell:1403.33 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:907.67 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:90.00 A
  • Max. Discharge Current:1900 (5sec)
  • Short Circuit Current:5102 A
  • Internal Resistance:1.86 mΩ
  • Terminal Type:I2 thread lead alloy terminal to accept M6 bolt
  • Terminal Torque:51.7±10.3 Kgf·cm / 44.9±9.0 Lbf·in / 5.1±1.0 N·m
  • Container Material:PP (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:69.50 / 153.22 kg / lb.
  • Length (L):558.0±2.5 / 21.97±0.10 mm / in
  • Width (W):126.0±1.5 / 4.96±0.06 mm / in
  • Height (H):323.0±2.5 / 12.72±0.10 mm / in
  • Design Life:Up to 10 years in standby service at 25°C; Eurobat (20°C): 12+ years, Very Long Life
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB XHRL12900WFTFR is a 12V front terminal valve-regulated sealed lead-acid battery in the XHRL-FT series, featuring AGM (Absorbent Glass Mat) technology with a gas recombination efficiency of up to 99% and a maintenance-free design. This model is primarily intended for high-rate float standby applications such as data center UPS, and its front terminal configuration makes front-of-cabinet wiring and maintenance more convenient. In terms of power performance, the battery has a nominal capacity of 900W @ 15min-rate, 10.02V per PCS @ 25°C. Individual cell power data is as follows: 2069.83 W/cell at 30 seconds 1.67 VPC @ 25°C, 1403.33 W/cell at 5 minutes 1.67 VPC @ 25°C, and 907.67 W/cell at 15 minutes 1.67 VPC @ 25°C. Maximum charge current is 90.00 A, maximum discharge current is 1900 A (5 seconds), short-circuit current is 5102 A, and internal resistance is 1.86 mΩ. In terms of dimensions, the battery is 558.0±2.5 mm long, 126.0±1.5 mm wide, and 323.0±2.5 mm high, weighing 69.50 kg. The terminal is an I2 thread lead alloy terminal, compatible with M6 bolts, with a terminal torque of 51.7±10.3 Kgf∙cm, equivalent to 44.9±9.0 Lbf∙in or 5.1±1.0 N∙m. The case material is PP (UL 94-HB), and a flame-retardant (94-V0) version is also available upon request. Electrical operating conditions: float charge voltage at 25°C is 13.5 to 13.8 Vdc/battery, equalize charge voltage is 14.4 to 15.0 Vdc/battery. Operating temperature: nominal temperature 25°C, discharge range -15°C to 50°C, charge and storage range -15°C to 40°C. Design life is 10 years at 25°C float standby service, and over 12 years Very Long Life under Eurobat (20°C) standard. Self-discharge: less than 10% after 90 days, storage up to 6 months at 25°C, up to 10 months with equalizing charge, fully charge before use, and charge earlier if storage temperature exceeds 25°C. The product features pure lead construction with proprietary elements, is manufactured according to IEC 60896-21/22:2004, and is UL1989 Recognized (MH14533). These characteristics make it suitable for applications such as data center UPS that require high-rate discharge and float standby.