Product Features

  • Valve-regulated lead-acid (VRLA) design
  • Absorbent glass mat (AGM) technology, maintenance-free, with gas recombination efficiency up to 99%
  • Pure lead construction with proprietary element formulation
  • Engineered for high-rate UPS and float standby power applications
  • Manufactured in compliance with IEC 61056-1/2:2012 and certified to UL1989 (MH14533)

Application Scenarios

  • Backup batteries for data center uninterruptible power supplies
  • UPS systems for server rooms
  • High-power backup power for industrial-grade UPS
  • Emergency power for medical equipment UPS
  • Backup power for financial system UPS
  • Backup power for telecommunications room UPS

Product parameters

  • Model:UPS12580
  • Voltage:12 Vdc
  • Nominal Capacity:580W @5min-rate
  • Watts per Cell:94.17 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:43.50 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:4.80 A
  • Max. Discharge Current:130 A
  • Short Circuit Current:575 A
  • Internal Resistance:11.80 mΩ
  • Terminal Type:F2 terminal (Faston Tab 250)
  • Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:2.83 / 6.24 kg / lb.
  • Length (L):150.9±2.0 / 5.94±0.08 mm / in
  • Width (W):64.8±1.0 / 2.55±0.04 mm / in
  • Height (H):98.6±1.0 / 3.88±0.04 mm / in
  • Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB UPS12580 belongs to the UPS series and uses Absorbent Glass Mat (AGM) technology. It is a 6V and 12V top-terminal valve-regulated sealed lead-acid (VRLA) battery. Its gas recombination efficiency reaches 99%, and it utilizes a pure lead construction with proprietary elements. This battery was developed for uninterruptible power supply (UPS) applications, particularly well suited for float-charge backup power scenarios in data center UPS systems. In terms of electrical parameters, the UPS12580 has a voltage of 12 Vdc and a nominal capacity of 580W @5min-rate (9.60V per PCS @ 25°C). At 5 minutes and 1.67 VPC, the power per cell is 94.17 W/cell; at 15 minutes and 1.67 VPC, the power per cell is 43.50 W/cell. The maximum charge current is 4.80 A, the maximum discharge current is 130 A, the short-circuit current is 575 A, and the internal resistance is 11.80 mΩ. At 25°C, the float charge voltage is 13.5 - 13.8 Vdc/battery, and the equalization charge voltage is 14.4 - 15.0 Vdc/battery. The terminal type is F2 terminal - Faston Tab 250, and the case material is ABS (UL 94-HB). A flame-retardant (94-V0) version is available upon request. The dimensions are 150.9±2.0 mm in length, 64.8±1.0 mm in width, and 98.6±1.0 mm in height, with a weight of 2.83 kg (6.24 lb). Under 25°C float charge conditions, the design life is up to 5 years, meeting the Eurobat (20°C) standard of 3-5 years for commercial applications. Regarding temperature conditions, the nominal temperature is 25°C, the discharge temperature range is -15°C to 50°C, and the charge and storage temperature range is -15°C to 40°C. At 25°C, the self-discharge rate is less than 10% over 90 days, and the battery can be stored for up to 6 months, but must be fully charged before use; if the storage temperature exceeds 25°C, earlier charging is required. The product complies with IEC 61056-1/2:2012 and is recognized under UL1989 (MH14533).