Product Features

  • VRLA (Valve Regulated Lead Acid) battery
  • Adopts AGM (Absorbent Glass Mat) technology, maintenance-free, with gas recombination efficiency up to 99%
  • Utilizes pure lead construction and proprietary element formulation
  • Designed for high-rate UPS and float standby power applications
  • Manufactured in accordance with IEC 61056-1/2:2012, UL1989 certified (MH14533)

Application Scenarios

  • UPS backup power: suitable for small and medium-sized data centers
  • Uninterruptible power supply: safeguards server rack operation
  • Network room power emergency: ensures continuous power supply
  • Standby UPS: supports medical imaging equipment
  • Fast discharge UPS: compatible with industrial control systems
  • Backup power: supplies power to laboratory precision instruments

Product parameters

  • Model:HR1234W
  • Voltage:12 Vdc
  • Nominal Capacity:34W @15min-rate
  • Watts per Cell:73.0 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:34.3 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:3.40 A
  • Max. Discharge Current:130 A
  • Short Circuit Current:349 A
  • Internal Resistance:19.0 mΩ
  • Terminal Type:F2 terminal (Faston Tab 250)
  • Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:2.50 / 5.51 kg / lb.
  • Length (L):150.9±2.0 / 5.94±0.08 mm / in
  • Width (W):64.8±1.0 / 2.55±0.04 mm / in
  • Height (H):98.6±1.0 / 3.88±0.04 mm / in
  • Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB HR1234W is a 12V valve-regulated sealed lead-acid battery featuring Absorbent Glass Mat (AGM) technology with a gas recombination efficiency of up to 99%. It is a high-rate discharge pure lead battery in the HR Series. This series was developed for lower-output UPS systems and backup power applications requiring rapid discharge, with data center uninterruptible power supplies as the officially designated application. In terms of specifications, the HR1234W has a nominal voltage of 12 Vdc and a nominal capacity of 34W @15min-rate (1.67 VPC @25°C). The 5-minute power is 73.0 W/cell, and the 15-minute power is 34.3 W/cell (1.67 VPC @25°C). Maximum charge current is 3.40 A, maximum discharge current is 130 A, short-circuit current is 349 A, and internal resistance is 19.0 mΩ. Weight is 2.50 kg (5.51 lb), with dimensions of 150.9±2.0 mm in length, 64.8±1.0 mm in width, and 98.6±1.0 mm in height. The terminal is F2-Faston Tab250. The case material is ABS (UL 94-HB), with a flame-retardant (94-V0) version available upon request. For charging parameters, the float voltage is 13.5 - 13.8 Vdc/battery (25°C), and the equalize voltage is 14.4 - 15.0 Vdc/battery (25°C). Operating temperature range: nominal 25°C, discharge -15°C to 50°C, charge/storage -15°C to 40°C. Under 25°C float conditions, the design life is up to 5 years, and the Eurobat (20°C) standard is 3-5 years. Self-discharge performance: less than 10% after 90 days at 25°C, with storage up to 6 months; a full charge is required before use. If storage temperature exceeds 25°C, recharge should be performed earlier. The battery meets IEC 61056-1/2:2012 standards and is UL1989 recognized (MH14533). Its maintenance-free design and pure lead construction make it well suited for data center UPS and other applications requiring high-rate discharge and float standby power.
link
Go to purchase
Telephone
13775032303
email
powercube@foxmail.com
wechat
wechat
Loading...