CSB GP1245 12V 16W VRLA Battery
CSB GP1245 VRLA battery, 12V 16W, with AGM technology, maintenance-free, suitable for general backup power applications such as security, emergency lighting, and medical equipment.
Taobao store
WeChat procurement
Product Features
- Valve-regulated lead-acid (VRLA) technology
- Maintenance-free, with absorbent glass mat (AGM) design providing up to 99% gas recombination efficiency
- Pure lead construction with proprietary element formulation
- Ideally suited for float standby power applications
- Manufactured to IEC 61056-1/2:2012 and UL1989 certified (MH14533)
Application Scenarios
- Backup power for security alarm panels
- Emergency lighting and evacuation indication devices
- Standby power for medical monitors and infusion pumps
- Access control systems and building intercom equipment
- Fire alarm and linkage control panels
- Small electronic instruments and testing equipment
Product parameters
- Model:GP1245 12V16W
- Voltage:12 Vdc
- Nominal Capacity:16W @15Min-rate
- Watts per Cell:34.8 (5-Min 1.67 VPC @ 25°)
- Watts per Cell:16.4 (15-Min 1.67 VPC @ 25°)
- Max. Charge Current:1.60 A
- Max. Discharge Current:90 A
- Short Circuit Current:168 A
- Internal Resistance:29.8 mΩ
- Terminal Type:F2 terminal (Faston Tab 250)
- Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
- Weight:1.34 / 2.95 kg / lb.
- Length (L):90.0±1.0 / 3.54±0.04 mm / in
- Width (W):70.0±1.0 / 2.76±0.04 mm / in
- Height (H):106.1±1.5 / 4.18±0.06 mm / in
- Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
- Float Charging Voltage:13.5 - 13.8 Vdc/battery
- Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
- Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
- Note:F1 terminal is available; Max Discharge Current = 60 A
Product details
The GP1245 is a general-purpose VRLA battery in CSB's GP series. It has a nominal voltage of 12 Vdc and a 15-minute rate nominal capacity of 16W at 1.67 VPC @25°C. The battery uses Absorbent Glass Mat (AGM) technology with a gas recombination efficiency of up to 99%, and its maintenance-free construction makes it ideal for float standby power applications.
In terms of electrical specifications, the GP1245 delivers 34.8 W/cell at the 5-minute rate (1.67 VPC @25°C) and 16.4 W/cell at the 15-minute rate. The maximum charge current is 1.60 A, the maximum discharge current is 90 A, the short-circuit current reaches 168 A, and the measured internal resistance is 29.8 mΩ. At 25°C, the float charging voltage should be set at 13.5 - 13.8 Vdc/battery, and the equalization charging voltage falls between 14.4 - 15.0 Vdc/battery.
In terms of dimensions, the battery measures 90.0±1.0 mm in length, 70.0±1.0 mm in width, and 106.1±1.5 mm in height, with a weight of approximately 1.34 kg. The terminal is F2 terminal - Faston Tab 250. The case is made of ABS (UL 94-HB), and a version compliant with the 94-V0 flame retardant rating is also available upon request.
Temperature range: nominal 25°C; discharge allowed from -15°C to 50°C; charging and storage between -15°C and 40°C. Under float charging at 25°C, the design life can reach up to 5 years, meeting the Eurobat (20°C) 3-5 year standard commercial grade requirement. The self-discharge rate is low, remaining less than 10% after 90 days of storage; it can be stored at 25°C for up to 6 months, but must be fully charged before use, and if the storage temperature exceeds 25°C, recharging is required sooner.
This battery is manufactured in accordance with IEC 61056-1/2:2012 and is UL1989 recognized (MH14533). It is officially positioned as a general-purpose battery, commonly used in applications such as security, emergency lighting, and medical equipment.